LiteLogDocs
English
LLMs.md

Check-in Monitoring (Dead Man's Switch)

Check-in monitoring (German: "Lebendmeldung") is LiteLog's lone worker protection — often called a dead man's switch. Employees working alone (e.g. night watch, patrol duty, single shifts on site) must actively check in at a defined interval. If the check-in fails to arrive, LiteLog escalates automatically in several stages — up to alerting the control center via push, e-mail, SMS, or automated phone call.

Assistance feature

Check-in monitoring is an assistance feature for protecting lone workers. It is not a certified personal emergency signal system (PNA) within the meaning of applicable standards. Check in your risk assessment whether a certified system is required.

Plan

Check-in monitoring with escalation is part of the Lone worker protection add-on (€29 per month — together with the force overview and a quota of 100 SMS per month). It is included in the Premium plan; with the other plans you book it as an add-on. See Choose a plan. Accounts created before the changeover keep their previous scope.

How it works

  1. Checking in — The employee submits a regular check-in via the status reporter widget on the app dashboard. Every status report counts as a sign of life and restarts the interval.
  2. Pre-alarm — If the employee does not check in within the interval, LiteLog sets the shift to pre-alarm: the employee receives a push prompt on their device asking them to check in, and the automation trigger "Proof-of-life overdue (pre-alarm)" fires.
  3. Main alarm — If there is still no check-in after the grace period expires, the main alarm follows: the automation trigger "Proof-of-life main alarm" fires, LiteLog automatically creates an incident with the employee's last known GPS position and sets their status to Emergency — visible in the live view.
  4. Unreachable — If the push prompt cannot be delivered (no device signed in, delivery failed), LiteLog additionally attempts an SMS to the phone number stored in the employee profile and fires the trigger "Proof-of-life undeliverable (worker unreachable)" — so the control center can react specifically to an unreachable lone worker.

Every check-in resets the escalation: as soon as a new status report arrives, monitoring returns to "OK" and the interval starts over.

Enabling

Check-in monitoring is disabled by default and can be switched on in two places:

Per shift template (planned shifts)

In the shift planner, open the shift dialog and enable Check-in monitoring (lone work) under "Advanced settings". There you define:

Setting Meaning Default
Interval How often the employee must check in 30 minutes
Grace period Additional time after the pre-alarm before the main alarm is raised 5 minutes

Monitoring then applies to all employees signed in within the planned shift window of this template.

Per property (spontaneous shifts)

For shifts without a planned template — e.g. spontaneous clock-in on site — enable check-in monitoring in the property on the Proof of Life & Status tab, again with interval and grace period. This property-level setting also acts as a safety net when a shift keeps running outside its planned window.

Feature activation

The property tab 'Proof of Life & Status' only appears when the personnel overview is enabled for your account.

Configuring the escalation chain

Who gets notified on pre-alarm, main alarm, or unreachability is controlled via the rules in the Automation area. Three triggers are available in the Safety category:

Trigger When
Proof-of-life overdue (pre-alarm) Interval expired, no check-in
Proof-of-life main alarm The grace period has expired as well
Proof-of-life undeliverable (worker unreachable) The prompt could not reach the employee

For each trigger you choose recipients and channels — push notification, e-mail, SMS, or automated phone call (SMS and calls require the add-on SMS & Calls or Lone worker protection, see Notifications & alarm channels). Default rules are pre-created for new accounts; adjust recipients and channels to your organization.

The reaction set for proof of life in the reaction defaults (out of the box: notify the supervisor) only applies to the main alarm and to undeliverable. The pre-alarm is a prompt to the worker. If supervisors should already hear about the pre-alarm, create a separate rule with the trigger “Proof-of-life overdue (pre-alarm)”.

Recommendation

Configure at least the main alarm with a channel that reliably reaches your control center — e.g. an automated call to the duty phone. The pre-alarm works well as a quiet early warning (push/e-mail), the main alarm as the loud one.

Traceability

  • Every escalation stage is logged — including the delivery outcome of the prompt to the employee. The course of an alarm can be reconstructed completely afterwards.
  • The main alarm automatically creates an incident in the Reports area with the last known position, employee, and property.
  • The live view shows the check-in state per employee in a dedicated column.

Good to know

Note

  • Every activity counts — Check-ins are submitted via the status reporter in the app; other status reports also reset the interval.
  • Choose the interval carefully — Too short an interval creates many interruptions, too long delays the alert. 30–60 minutes is common, depending on the risk level.
  • Maintain phone numbers — For the SMS fallback on unreachability to work, a phone number must be stored in the employee profile.
  • Deliberate planner choice — If check-in monitoring is explicitly disabled on a shift template, it stays off for shifts within its window even when the property has check-in monitoring configured.

Permissions

Permission